| Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
|---|---|---|---|---|
| COMBI Neutral 70/35 NG | ||||
| COMBI Neutral 70/35 NG -1 | 42 | 0.7 | 33 | 63 |
| COMBI Neutral 70/35 NG -2 | 46 | 0.6 | 33 | 63 |
| COMBI Neutral 70/35 NG -3 | 42 | 0.7 | 32 | 63 |
| COMBI Neutral 70/35 NG -4 | 46 | 0.6 | 32 | 63 |
| COMBI Neutral 50 | ||||
| COMBI Neutral 50 -1 | 42 | 0.7 | 25 | 46 |
| COMBI Neutral 50 -2 | 46 | 0.6 | 25 | 46 |
| COMBI Neutral 50 -3 | 42 | 0.7 | 24 | 46 |
| COMBI Neutral 50 -4 | 46 | 0.6 | 24 | 46 |
| COMBI Neutral 60 | ||||
| COMBI Neutral 60 -1 | 42 | 0.7 | 29 | 54 |
| COMBI Neutral 60 -2 | 46 | 0.6 | 29 | 54 |
| COMBI Neutral 60 -3 | 42 | 0.7 | 29 | 54 |
| COMBI Neutral 60 -4 | 46 | 0.6 | 28 | 54 |
| Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
|---|---|---|---|---|
| SELEKT 74/42 | ||||
| SELEKT 74/42 -1 | 42 | 0.7 | 39 | 66 |
| SELEKT 74/42 -2 | 46 | 0.6 | 39 | 66 |
| SELEKT 74/42 -3 | 42 | 0.7 | 38 | 66 |
| SELEKT 74/42 -4 | 46 | 0.6 | 38 | 66 |
| SELEKT 70 | ||||
| SELEKT 70 -1 | 42 | 0.7 | 34 | 63 |
| SELEKT 70 -2 | 46 | 0.6 | 34 | 63 |
| SELEKT 70 -3 | 42 | 0.7 | 33 | 63 |
| SELEKT 70 -4 | 46 | 0.6 | 33 | 63 |
| Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
|---|---|---|---|---|
| SUNSTOP Neutral 50 T | ||||
| SUNSTOP Neutral 50 T -1 | 42 | 0.7 | 33 | 42 |
| SUNSTOP Neutral 50 T -2 | 46 | 0.6 | 33 | 42 |
| SUNSTOP Neutral 50 T -3 | 42 | 0.7 | 31 | 42 |
| SUNSTOP Neutral 50 T -4 | 46 | 0.6 | 31 | 42 |
| SUNSTOP Blau 50 T | ||||
| SUNSTOP Blau 50 T -1 | 42 | 0.7 | 32 | 40 |
| SUNSTOP Blau 50 T -2 | 46 | 0.6 | 31 | 40 |
| SUNSTOP Blau 50 T -3 | 42 | 0.7 | 30 | 40 |
| SUNSTOP Blau 50 T -4 | 46 | 0.6 | 30 | 40 |
| SUNSTOP Blau 30 T | ||||
| SUNSTOP Blau 30 T -1 | 42 | 0.7 | 19 | 24 |
| SUNSTOP Blau 30 T -2 | 46 | 0.6 | 19 | 24 |
| SUNSTOP Blau 30 T -3 | 42 | 0.7 | 19 | 24 |
| SUNSTOP Blau 30 T -4 | 46 | 0.6 | 18 | 24 |
| SUNSTOP Silber 20 T | ||||
| SUNSTOP Silber 20 T -1 | 42 | 0.7 | 15 | 17 |
| SUNSTOP Silber 20 T -2 | 46 | 0.6 | 15 | 17 |
| SUNSTOP Silber 20 T -3 | 42 | 0.7 | 14 | 17 |
| SUNSTOP Silber 20 T -4 | 46 | 0.6 | 14 | 17 |
| Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
|---|---|---|---|---|
| SUPERSELEKT 60/27 | ||||
| SUPERSELEKT 60/27 -1 | 42 | 0.7 | 26 | 52 |
| SUPERSELEKT 60/27 -2 | 46 | 0.6 | 26 | 52 |
| SUPERSELEKT 60/27 -3 | 42 | 0.7 | 26 | 52 |
| SUPERSELEKT 60/27 -4 | 46 | 0.6 | 26 | 52 |